Use of crystals beyond usual acceptance, summarised from email below: FNUF from 0.7 - 1.0 to be glued with LIGHT BLUE (LB) VPTs for 2x5 partials Muind 1.5-2.0 to be glued with LIGHT BLUE (LB) VPTs for 2x5 partials FNUF from 0.7 - 1.0, Muind < 1.6 for 4x5 and 3-2-1 partials on inner EE From: Dave Cockerill Sent: 28 September 2006 12:24 To: Etiennette Auffray Hillemanns; Herve Cornet Cc: Philippe Bloch; Sergei Gninenko; Nikolai Golubev; Vassili Kachanov; Tiziano Camporesi Subject: Gluing the remaining EE xtals at CERN Importance: High Hi Etiennette, Herve, Following our phone call here is what I understand we agreed: GOOD XTALS FNUF (<0.7) ---------------------- BTCP 2001 and 2003, 31 xtals 29 to be glued with GREEN VPTs 2 to be glued with BLUE VPTs SIC good 3 xtals 3 to be glued with BLUE VPTs The 5 blue will complement the existing 20 BLUE, already glued, to give a complete SC. The gluing of 34 xtals to be done tomorrow, Fri Sep 29. LESS GOOD XTALS --------------- BTCP FNUF from 0.7 - 1.0 10 xtals 10 to be glued with LIGHT BLUE (LB) VPTs (for 2x5 partials) SIC Muind 1.5-2.0 meas at SIC 21 xtals 21 to be glued with LIGHT BLUE (LB) VPTs (for 2x5 partials) SIC Muind 1.5-2.0 meas at CERN/Rome 5 xtals 5 to be glued with LIGHT BLUE (LB) VPTs (for 2x5 partials) AWFUL XTALS ----------- SIC Muind > 2.0 6 xtals NOT to be used yet XTALs at Rome ------------- SIC 55 xtals - expected back, as soon as measured, during Oct and Nov Comments -------- Dave to bring a further 5 blue VPTs to Herve today. Dave to prepare 50 LIGHT BLUE (LB) VPTs for the partial SCs. The totals above give a further 4 SCs, plus 25 other BLUE glued in bat 27, = 11 + 5 = 16 SCs Only 4 more SCs needed for Dee4 (100 xtals). The first batch in 2006 from SIC would be interesting to have in Dee4 for the beam tests next year.