From: Hill, JA (John) [J.A.Hill@rl.ac.uk]
Sent: 06 December 2005 12:12
To: Robert Loos (E-mail)
Cc: David Barney; Piet WERTELAERS (E-mail); Cockerill, DJA (David); Bell, KW (Ken)
Subject: Fixture checks on EE Environmental screen

Attachments: cmseethm0002-vAC.plt; cmseethm0004-vAA.plt
Hi Rob,
Once again thanks for meeting with us last week.
I have looked at some of the details you requested following our meeting.
The Z dimension you seem to have referenced on your drawing (Z=3911) is the EE and HE interface plane, this number is useful and should be kept as a cross reference between EE-HE-ES detectors.
On the other matter of ES spider fixtures I have checked the Russian environmental shield drawings. Nothing has changed since the End Cap EDR in Sept 2002. The phi positioning of the ES fixture holes checks correctly however the radii at which these holes are dimensioned on your diagrams are not. Andrei Levine presented the interfaces during the EDR and has these fixture holes at R1542mm. This does not correspond with the R1545 number you have. Details can be found in CMS ECAL EDR-06 section 3.5 however I have downloaded some relevant drawings (HPGL) from CDD and attached them for your reference.
 
Best Regards
    John
 
 
 
John A Hill IEng MIED
Senior Mechanical Engineer

CCLRC Rutherford Appleton Laboratory
Project Engineering Division, Chilton, Didcot, Oxon OX11 0QX

T+44 (0)1235 446611
F+44 (0)1235 446863
J.A.Hill@rl.ac.uk
http://www.clrc.ac.uk