Here is a list of items which we think will have bar codes for EE, after discussing with various people. Total: 6 functional barcodes: 1) VPT 2) Crystal ---------------------------------------------------------------- VPT to xtal gluing done in bldg 27. Still in discussion, VPT HT test before or after gluing to xtal => CRISTAL check: Scan VPT barcode and xtal barcode to associate the two together ------------------------------------------------------------------------- => CRISTAL check: scan the vpt/xtal for the corresponding alveolar pocket of the SC ------------------------------------------------------------------------- 3) SC ------------------------------------------------------------------------ Barcode on one 'front insert' of the SC after 25 vpt/xtals have been inserted and glued into place => CRISTAL check: if SC high voltage soak test was OK ------------------------------------------------------------------------ 4) Positional spacer -------------------------------------------------------------------- Aluminium block which orients the SC in 3 dimensions and defines its position on a Dee => CRISTAL check: Scan Positional spacer barcode and SC barcode to associate the two together -------------------------------------------------------------------- 5) Slot on Dee backplate --------------------------------------------------------------------- Each SC has a slot on the Dee backplate for cables. Near this slot should be a bar code. => CRISTAL check: that positional spacer and Dee slot are consistent -------------------------------------------------------------------- 6) EE backplate -------------------------------------------------- The backplate should have a barcode to identify it -------------------------------------------------- We do not see the need for barcodes on Alveolars - will pass a go/no go test HT cards/umbilical inside SC - will pass a go/no go test