HV Multibox tester


2006
Proposed rear panel items for services to multibox tester, D Cockerill 17.8 ppt
HV read relays used at RAL, sent to CERN by Laurie Lintern,
        2
0 Pickering 104-1-A-12/2D Reed relays
        Rated at 1.5kV. No failures at RAL.

Progress with the multibox tester, D Cockerill 27.3

DSCN0531.JPG (743040 bytes) DSCN0532.JPG (675496 bytes) DSCN0533.JPG (742580 bytes) VPT to crystal gluing tests, preparation of HT test box 27.3

Photos of the APD+crystal multibox tester, D Cockerill, 8.3

DSCN0418.JPG (761470 bytes) The APD+crystal multibox test setup. The crystals are spaced by 80mm from one another
DSCN0419.JPG (734368 bytes) Detail showing the arrangement to inject light to the crystals for APD checking.
The LED is on continuously, DC. The switch box in view on top of the block actuates a sliding shutter which rises to allow the LED light through to the crystal. An individual pcb (~5.5x5.5 cm2) is used per crystal.

The block/pcb can be replaced with a pcb+mount optimised for VPT tests.
There is about a 60mm gap from the crystal to the front panel of the HT test box.

DSCN0420.JPG (700614 bytes) The cable runs serving the LEDs and the 'System On' LEDs, collected at the side of the test box.
DSCN0421.JPG (757791 bytes) Detail of the connections from the APDs to the dedicated pcb for APD readout and HV.

This will be removed and replaced with an EE HV filter card + 5 stephenson preamps on one mount, for VPT testing.