Summary of EE/ES testbeam activities
2007
![]()
H4, Dee4 (20 SCs)
Data taking 28 June - 8 August
H2,
Pre-shower+E0' (4 SCs)+HE in various combinations
Data taking 25 July - 23 August, 19 Sep - 10 Oct
2004 SM10 at H4 7.10-15.11 - first use of MGPA
electronics readout
Preshower at H4 27-30.9
E0prime at H4 22.6-6.9 with SC03 (VPTs) and SC04 (APDs)
E0prime at H4 11.5-21.6 with SC03 (VPTs)
2003
SM1 at H4 17.10-30.10
SM0 at H4 13.8-13.10 included irradiation studies
1999 Prototype pre-shower array with prototype SC at H4
First SC,
with 25 prototype VPTs, installed at H4 and then at H2, with data from 0T to 3T
1998 3x3 array in H4
2009
ECAL barrel crystal and module borders energy corrections for unconverted
photons, Tourneur, Seez 22.1
draft
Studies of the ECAL Endcap Energy Resolution using 2007 Test beam data,
CMS DN-2009/002, S Beauceron, P Bloch 3.2
final
Studies of the ECAL Endcap Energy Resolution using 2007 Test beam data, S
Beauceron, P Bloch 3.2 data:
- fit results
from energy scans, noise taken from pedestal data: stoch, s_err, const, c_err
3x3
5x5
- fit results
from energy scans, all 3 terms fitted: stoch, s_err, const, c_err,
noise, n_err
3x3
5x5
- noise
values used from J Fay pedestal data with: Xtalnumber
iX iY noise1x1 noise3x3 noise5x5
txt
EB & EE precalibration, F Cavallari, DPG
9.10.08
Sasha Ledovskoy, file for Konstantinos, on lab xtal/VPT and Dee4 info
channel_v4.txt
Konstantinos Theofilatos - Dee4 calibration file
V03.txt
- talks in '07 and '08 on Dee4 calibration
4.9.08
21.11.07
7.11.07
10.10.07
26.9.07
13.8.07
18.7.07
2008
Cluster containment corrections using ECAL position measurements at the 2006 H4
testbeam, Meridiani, Rovelli 19.12
draft3
Dan Andelin thesis, 'Study
of CMS Forward EM Calorimeter Performance from Testbeam Data',
H4 2007 1.12 htm
pdf
Ref from 27.4.07, Intercalibration at 2006 ECAL testbeam with the single crystal
technique, Benaglia et al, DN 2007/001
2007
Dee4 at H4 3.8.07-5.2.08
VPT (in)stability impplications for H4, R Yohay,
DPG 12.8
ppt
E0prime for H2 and HE wedge at H2 1.6
Sketch for E0prime at H2 with HE, D Cockerill 28.2
ppt
2006 No entries
2005
Dee 4 at H4 and planning (text file and mpp), D Cockerill/J Greenhalgh 17.6
ppt
txt
mpp
Needs for Dee4 at H4, Nov 2006, D Cockerill may 05
htm
2004
SM10 at H4 7.10-15.11
Preshower at H4 27-30.9
E0prime at H4 22.6-6.9 with SC03 (VPTs) and SC04 (APDs)
E0prime at H4 11.5-21.6 with SC03 (VPTs)
Workshop Analysis Calorimetry H4, WACH4, Mar 8-9 04 talks
Milano info
2003
SM0 at H4 13.8-13.10 included irradiation studies
SM1 at H4 17.10-30.10
2003 SPS programme, 15 April 2003 pdf
2002
Workshop Analysis Calorimetry H4, WACH4, Nov 27-28 02 link
M0' testbeam homepage, 2002 link
Test
Results from a Prototype Lead Tungstate Crystal Calorimeter with Vacuum
Phototriode Readout for the CMS Experiment, M. Apollonio et al., NIM
A484 287-298
pdf
doc
2000
1999/2000
Test beam data, info and analysis , H Heath
link
Temperature data for 1998 and 1999 test beam runs, F Jacob 22.08 txt
A Study of the Monitoring of Radiation Damage to CMS ECAL Crystals, Performed at X5-GIF,
G. Davies et al., CMS NOTE-2000/020 pdf
Results from the 1999 Beam Test of a Preshower Prototype ( using the 1999 5x5 supercrystal array),
D. Barney et al., CMS NOTE-2000/001 pdf
Energy Resolution of a Prototype Lead Tungstate Crystal Matrix with Vacuum Phototriode Readout for the CMS
Endcap Electromagnetic Calorimeter, G.J. Davies et
al., CMS NOTE 2000/014 pdf
Coherent Noise in the CMS ECAL Endcap Testbeam,
H.F. Heath, CMS IN 2000/011 pdf
Portability of Calibration Constants in the CMS ECAL Endcap Testbeam,
H.F. Heath,
CMS IN 2000/010 pdf
1999
1999/2000
Test beam data, info and analysis , H Heath
link
Virtual focus turntable proposals, G Barber 12.11
link
Preshower plus EE resolution for electrons at 180 GeV ps, eps, pdf
H4/H2 : Study of xtal+vpt output from B=0T
(H4) to 3T (H2) ps
1998
H4 : Summary table of results for 1998, 30.9.98 ps
Longitudinal Uniformity Scans of PbWO4 Crystals Using 120 GeV Electrons in the H4 Testbeam in 1997,
G. J. Davies et al., CMS NOTE-1998/057 pdf
Study of ECAL Energy Reconstruction Algorithms in Test Beam Data, C Seez et
al.,
CMS NOTE-1998/030 pdf
Lateral Uniformity of Energy Response in the August 1997 ECAL Test Beam
Matrix, C Seez et al., CMS NOTE-1998/023 pdf
Test Beam Irradiation Catalogue for 1997 and 1998, C Seez, CMS IN-1998/026 pdf
1997
Radiation Damage and Longitudinal Uniformity, C Seez et al., CMS IN-1997/022 pdf
1996
Longitudinal Uniformity Scans of PbWO4 Crystals Using 120 GeV Electrons in H4 Testbeam,
D
Barney et al., CMS NOTE-1996/006 pdf